Centrifugal cantilever pump: operating principle and technical characteristics. Monoblock pump

  • Overall and connecting dimensions of KM type pumps.

KM pumps, in accordance with generally accepted classifications, include:

– by design – cantilever (unlike K-type pumps

, the impeller is located directly on the shaft of a specially designed drive motor or on an intermediate shaft, which is also mounted on the shaft of a conventional flanged or combined mounting type electric motor). - according to the principle of operation - centrifugal, dynamic, bladed, with an output flow at the exit of the radial type impeller (impeller - closed type).

Cantilever monoblock pumps KM

by type of pumped medium, they are designed mainly for water (except sea water) and liquids similar to water in density, viscosity (up to 36 cSt), with a pH value from 6 to 9. KM monoblock pumps for special purposes are also produced:

– for pumping chemically active media (XM pump), – light petroleum products (KMN pump), – food products – other monoblock pumps for various media. Most household pumps are produced in a monoblock design.

Temperature of the pumped liquid for KM water pumps:

– with an stuffing box seal – from 0 to 80 o C, – with a mechanical (end) seal – from 0 to 105 o C (short-term excess of the maximum temperature up to 120 o C is allowed).

– for pumps with gland seal – 3.5 atm. – for pumps with mechanical seal – 6 atm.

KM pumps allow a small amount of mechanical impurities in the pumped liquid: up to 0.2% by weight. Particle size in impurities is up to 0.2 mm. Suction height ( KM pump is not self-priming

) varies depending on the brand of pump. To determine the suction height of the pump (when pumping water from an open source, at normal atmospheric pressure, at a water temperature of 20 o C), you can use a simplified formula

Cantilever monoblock pumps are devices with a centrifugal design; their type is single-stage monoblock; the nature of the supply of the working liquid mass is unidirectional. The scope of application of these pumps is water supply, circulation processes and heating systems. They are used for pumping water and liquids similar to it in physical properties.

This includes clean, drinking water, industrial water for use in production, the pH should be from 6 to 9. The exception is sea water. Pumps can also pump other liquids that are close to water in density, viscosity and chemical activity. Solid inclusions should not exceed 0.2 mm, the concentration per unit volume should be up to 0.1%.

The temperature regime of the working fluid for devices such as cantilever monoblock pumps is from 0 to 850C (with a single gland seal) or up to 1050C (if the mechanical seal is single). Cantilever monoblock pumps are not allowed for use in industries with explosion and fire hazards, as well as for pumping flammable liquids. The following materials are used in the pumps: the flow part is made of gray cast iron, the shaft end seal is a single stuffing box.

Design of a cantilever monoblock pump

The equipment of such equipment as cantilever monoblock pumps, by analogy with cantilever pumps, has a centrifugal wheel, a pipe for receiving and discharging liquid mass, a spiral-ring outlet, a housing, and clamps. The impeller is made in the form of two disks with curved blades between them. Cantilever monoblock pumps and cantilever pumps have differences in weight and size and, in addition, in the design of connections to the electric motor.

In cantilever monoblock pumps, an extended shaft in the motors is used for drive. The impeller is attached to the end of this shaft. This connection method is more reliable due to the smaller number of bearing units.

The design of mechanisms such as cantilever monoblock pumps consists of a volute casing with axial suction and radial discharge pipes, the angle between them is 900. The impeller is mounted on the electric motor shaft. The pump housing and the electric motor are connected by a drive lantern; an O-ring is located between the lantern and the pump housing. A coupling is attached to the center of the lantern. The design of the pump allows for the removal of the electric motor and impeller without dismantling the pump housing. Both the pump and the electric motor are mounted on the same steel frame.

Operating principle, installation

The principle of operation of a cantilever pump is not complicated and is determined by the main design features. When the electric motor is turned on, the blades on the impeller begin to rotate rapidly. Due to this, strong pressure is built up and the liquid is pumped, being drawn into one hole and squeezed out of another, located on the opposite side of the disk. The speed of pumping water increases significantly when the wheel begins to rotate faster.

However, excessive acceleration can cause cavitation due to reduced inlet pressure levels. More specifically, the cavitation process is caused by vapor formation accompanied by condensation of air contained in the working fluid. For this reason, selecting the appropriate cantilever pump should always be the responsibility of an experienced professional.

To operate a cantilever pump, a reliable base is required in the form of a concrete foundation, which is approximately 20 cm larger in size than the pump housing. The thickness of the base must be at least 20 cm. The frame of the pumping device must be firmly fixed to the base. For this purpose, special anchors are often used. A special gasket is placed between the foundation slab and the device body to absorb vibration. On the nozzles of the pumping device in front of the pipe structures, it is necessary to install shut-off valves, as well as counter flanges, which ensure a sufficiently reliable connection of the nozzles and pipe structures.

Operating principle of a cantilever centrifugal monoblock pump

During the operation of cantilever monoblock pumps, the electric motor transmits torque to the impeller through the shaft. The inlet pipe is filled with liquid, which is forcefully ejected through the outlet pipe with greater pressure and speed compared to the inlet pipe. This process occurs through centrifugal force, which arises from the rotation of the impeller.

When liquid is ejected into the outlet pipe, a vacuum occurs in the center of the wheel, resulting in a pressure difference between the pump inlet and its center. Under the influence of a pressure difference, the product moves from the inlet pipe to the pump housing, where it is again captured by the centrifugal force of the wheel, after which the process of moving the liquid is repeated.

The precision of the technological execution of the design of such equipment as cantilever monoblock pumps allows the use of high-quality technical functioning of the devices over a long period, without the need for replacement or repair.

For cold and hot water - these are units designed for pumping liquid (water); by type of design: horizontal, single-stage, with one-way liquid supply to the impeller located at the end of the pump shaft. In terms of design, technical characteristics, and areas of application, they are centrifugal pumps for water. The main qualities of cantilever monoblock pumps and cantilever pumps are high quality production and long service life, based on the high reliability of these units.

Repair

Overhaul of the pump is carried out after the installed resource of the unit has been exhausted. The optimal duration of the operating period is determined by the model and brand of the pumping unit.

The most common problems during operation are:

  • No pressure after startup. Similar problems can arise as a result of clogging or the formation of voids in the impeller, which must be filled with liquid;
  • Poor productivity may be due to wear on the impeller or increased resistance in the feed hose;
  • Wear of insulating devices or a significant increase in pressure in the system can cause leakage;
  • Bearings may overheat due to changes in shaft alignment or insufficient lubrication;
  • Increased vibration and high noise during operation may indicate that the cavitation reserve is increased, the pump is not tightly fixed on the concrete platform, or the bearings require replacement.

During operation, cantilever pumps require constant maintenance, as well as preventive repairs approximately every 3 months.

Purpose of cantilever pumps and cantilever monoblock pumps

Cantilever pumps (type K) and cantilever monoblock pumps (type KM) are single-stage centrifugal pumps with a one-way liquid supply to the impeller. They are designed for pumping water (except seawater) and other liquids similar to water in density, viscosity and chemical activity, temperatures from 0°C to 85°C (on special order up to 105°C), containing solid inclusions up to 0. 2 mm, the volume concentration of which does not exceed 0.1%.

Cantilever pump

Features of cantilever shaft placement

The cantilever placement of the shaft makes it possible to design the most simple and functional products, during the operation of which water passes through the inlet and falls directly onto the impeller. After this, the liquid is discharged into a spiral-shaped casing, and then moves under pressure through the water supply.

In such structures, 2 types of supports are used:

  1. Ball.
  2. Sliding friction devices.

Console-type models are used in most cases for working with clean water and are always installed in a horizontal position. The inlet for the working fluid is located only on one edge. The device can pump pressure up to 90 meters in height. The operating principle of the products is similar to other centrifugal pumps. To reduce axial pressure, the device is equipped with a special seal, as well as additional holes for unloading, located in place of the wheel hub.

Symbols of cantilever pumps and cantilever monoblock water pumps

TO

– horizontal cantilever pumps with support on the housing, with rotation transmitted from the engine through an elastic coupling.
KM
,
KMM
– cantilever monoblock (KMM – modernized) pumps. The pump impeller is mounted on the end of an extended electric motor shaft.

Pump symbol according to GOST 22247-96: Consider, for example, the K80-50-200-S-UHL4

.
K
– pump type (cantilever);
80
– nominal diameter of the inlet pipe, mm;
50
– nominal diameter of the outlet pipe, mm;
200
– nominal diameter of the impeller, mm;
C
– symbol of a single pump shaft seal or
SD
– double seal;
UHL
– climatic version;
4
– category of unit placement during operation of
a cantilever monoblock pump

Equipment K 20 30 and K 30 30 – areas of application of pumps

The K 20 cantilever centrifugal pump is equipped with an axial supply in a horizontal position. It is used for pumping various liquids, while being located in a horizontal position. The K20 30 shaft is equipped with a single mechanical seal. Models with double gland seals can also be found on sale.

The K 30 30 pump is used in more areas. It is successfully used in industrial pumping stations, heating pipelines, urban and rural water supply. However, this equipment cannot be used in explosive atmospheres.

Among the technical characteristics of the pump of this modification, the following should be highlighted:

  • Pressure to a depth of up to 30 m;
  • Productivity – maximum 20 m3/h. work;
  • Rotation speed – 3 thousand rpm;
  • Weight – 78 kg;
  • Power – 4000 Watt.

The unit has high build quality, reliability and does not require constant maintenance.

Operating principle and design of cantilever pumps and cantilever monoblock pumps

The main working part of a cantilever water pump is a centrifugal wheel. A centrifugal wheel consists of a pair of disks with blades located between them, connected into a common structure. The impeller blades have a smooth bend in the direction opposite to the direction of rotation of the impeller. This device is the most common. With such a device, the impeller is called closed. Sometimes you can find cantilever centrifugal pumps with an open impeller design, which in this case consists of a single disk. When the impeller rotates, the liquid inside it is subjected to a centrifugal force directly proportional to the distance of a unit of liquid from the center of the impeller and the square of the angular speed of rotation of the impeller. Under the influence of this centrifugal force, water is pushed out of the impeller into the pressure (outlet) pipe of the cantilever centrifugal pump, and a vacuum occurs in the central part of the impeller, and high pressure occurs in its peripheral part. The flow of liquid from the suction pipeline occurs due to the difference in pressure at the surface of the water in the receiving tank and in the central part of the wheel.

Typically, cantilever centrifugal pumps include single-stage centrifugal pumps, cast iron in construction material, with one-way liquid supply, the impellers of which are located at the end of the electric motor shaft. Other types of industrial pumps, such as sewage, chemical, and soil pumps, also have this type of design.

The design of cantilever and cantilever monoblock pumps at the location of the sealing unit depends on the temperature of the pumped liquid, as well as the pressure in the supply pipe at the inlet to the pump. Barrier fluid is not supplied to the single soft seal. In the double gland seal, at a temperature of the pumped liquid up to 90°C, the barrier liquid is supplied to the dead end, and at a temperature above 90°C - to the flow. The pumped liquid from the pressure pipeline can be supplied to the single mechanical seal. In the double mechanical seal of the cantilever pump, the barrier fluid is supplied only to the flow path. In all cases, the barrier fluid is supplied under pressure exceeding the pressure before compaction by 0.5...1.5 kgf/cm2. Any non-toxic and non-explosive liquid with a temperature not exceeding 40°C, containing particles up to 0.2 mm in size with a volume concentration of up to 0.1%, can be used as a barrier liquid. The maximum permissible excess pressure of the pumped liquid at the inlet: for cantilever water pumps with a gland seal - 3.5 kgf/cm2, for cantilever and cantilever monoblock pumps with a mechanical seal - 8 kgf/cm2.

The maximum permissible external water leakage through the gland seal of a cantilever centrifugal pump is up to 3 l/h (liquid must leak through the gland to lubricate and cool the sealing surface). Leakage through the mechanical seal is significantly less and, ideally, can be close to zero.

Scope of application

Due to their certain versatility in terms of the characteristics of the pumped liquid, centrifugal pumps have found a huge range of applications. They are used in the oil and gas industry, installed in household water supply networks, and work at gas stations.

Without centrifugal pumps, compact and reliable, not a single firefighting aircraft that takes water in open reservoirs can do. Installations of this class are used by city fire services. It is simply unrealistic to list all the areas of application of devices with a centrifugal supercharger.

Table of technical characteristics of cantilever pumps and cantilever monoblock pumps.

Pump nameSupply, m3/h.Napor, m.Engine, kW* rpmd in, mmd out, mmWeight, kgDimensions, mm. LxBxH
K8/188182,2*3000403258764*257*323
K50-32-12512,5202,2*3000503258764*257*323
K20/3020304*3000504078827*299*332
K65-50-12525203*30006550120730*368*325
K65-50-16025325,5*30006550140925*408*338
K45/3045307,5*300050401261030*332*413
K80-50-200505015*300080502551120*458*455
K80-50-200a454011*30008050185990*428*425
K100-80-1601003215*3000100802751105*458*450
K100-80-160a902611*3000100802001105*458*450
K100-65-2001005030*3000100653701290*498*510
K100-65-200a904018,5*3000100653251265*498*475
K100-65-2501008045*3000100654851440*568*620
K100-65-250a906737*3000100654601390*568*605
K160/301603030*15001501004201515*515*555
K160/30a14028,622*15001501004001465*515*555
K160/30b1402218,5*14501501003401495*505*530
K150-125-2502002018,5*15001501254101325*475*455
K150-125-3152003230*15001501254221375*540*610
K290/302903037*15002001505501645*575*630
K290/30a2502430*15002001504601555*515*585
K200-150-2503152030*15002001504221375*540*610
K200-150-3153153245*15002001505701665*600*720
KM50-32-12512,5202,2*3000503247500*200*202
KM65-50-16025325,5*3000655076578*250*272
KM80-50-200505015*3000805090790*350*420
KM80-65-16050327,5*3000806590630*320*362
KM100-80-1601003215*300010080195790*350*420
KM100-65-2001005030*300010065260865*400*440
KM150-125-2502002018,5*3000150125195870*370*705

Our Company offers a full range of industrial and domestic pumps, including cantilever pumps, drainage, self-priming, fecal, irrigation, well and many, many others. You can familiarize yourself with the range and technical characteristics on the website page.

Cantilever monoblock pumps are horizontal single-stage cantilever pumps with a one-way liquid supply to the impeller. These pumps, like conventional cantilever pumps, are designed for pumping clean water (except sea water) under stationary conditions, with pH = 7, temperature from 0 to 85 ° C, containing solid inclusions up to 0.2 mm in size, the volume concentration of which does not exceed 0.1%, as well as other liquids similar to water in density, viscosity and chemical activity. The scope of application is identical to the scope of application of cantilever pumps of type K. The advantage of cantilever monoblock pumps is their compactness compared to cantilever pumps of type K. This advantage makes it possible to install pumps in a limited area. However, there is also a drawback that after turning the impeller it is impossible to select a three-phase electric motor with a lower power. The reason lies in the design of the pump and the monoblock electric motor with an extended shaft specially designed for the pump. The cast-iron pump casing conceals its main working element – ​​the centrifugal impeller (cast iron grade SCh20 or SCh25). The role of the pump shaft is actually played by the shaft of a three-phase electric motor, since the pump impeller is mounted on the electric motor shaft. There are two main types of shaft seals: single gland seal and single mechanical seal. The stuffing box seals are designated by the letter “C” to the main brand; if it is not there, then it is implied. Leakage through the gland seal is no more than 2 l/h, to lubricate and cool the soft packing. Single mechanical seal – brand index “5”. External leakage through the mechanical seal is no more than 0.03 l/h. Pumps with mechanical seals can pump liquids with temperatures from 0 to 115 ° C. Pressure at the pump inlet is up to 8.0 kgf/cm2.

An example of a pump unit symbol:

KM80-50-200 a-5 UHL4

  • KM
    – pump type – monoblock console pump, centrifugal
  • 80
    – diameter of the suction inlet pipe, mm,
  • 50
    – diameter of the pressure outlet pipe, mm,
  • 200
    – nominal diameter of the impeller, mm,
  • a
    – first turning of the impeller,
  • 5
    – designation of a single mechanical seal,
  • UHL4
    – climatic version and placement category.

Manufacturing of console cranes at a competitive price

Do you need a jib crane, but don’t know who you can trust to make it? Ours carries out a full cycle of work on the production of jib cranes of any type. We are ready to develop a crane equipment project and will undertake its implementation on a turnkey basis - including delivery and installation at the customer’s site. Atlant-Kran's production facilities are located in the Moscow and Rostov regions, but you can use our services in any region of Russia, as well as neighboring countries. If you need more information, request a call back and our specialist will answer all your questions.

Rating
( 2 ratings, average 4.5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]