How do you know if a transformer is a step-down or step-up transformer?


What is a transformer for?

The main property of a transformer is the conversion of voltage or current to the required value and galvanic isolation - this is a very useful property of transformers, which we will discuss below.

And so, for example, in a home electrical outlet the voltage is 220 volts 50 hertz ( AC - this is how alternating voltage is indicated on circuits and power supplies - AC 220v 50hz ), i.e., alternating voltage, and to power a laptop we need 18 volts direct current ( DC - this is the designation for constant voltage DC 18v ). With the help of a transformer, we can convert the voltage to the required value and then rectify it. After which, this voltage will be suitable to power your laptop. Not quite clear? The missing term is Transformation Ratio.

How to calculate transformer windings

Purpose of transformers

Different types of transformers are used in almost all power supply circuits for electrical devices and when transmitting electricity over long distances.

Power plants produce a current of relatively low voltage - 220 , 380 , 660 V. Transformers, increasing the voltage to values ​​​​of the order of thousands of kilovolts , can significantly reduce losses when transmitting electricity over long distances, and at the same time reduce the cross-sectional area of ​​power line wires.

Immediately before it reaches the consumer (for example, a regular household outlet), the current passes through a step-down transformer. This is how we get the 220 Volts we are used to.

The most common type of transformers is power transformers . They are designed to convert voltage in electrical circuits. In addition to power transformers, various electronic devices use:

  • pulse transformers;
  • power transformers;
  • current transformers.

What types of transformers are there?

Autotransformer (LATR) is a step-down transformer with one winding, from which, using the rheostat handle, a voltage from 1 to 180 volts is obtained. Such trances are used in laboratory conditions to test various devices. In everyday life it is used in some voltage regulators.

An oil transformer is a monster transformer! with winding pipes filled with mineral oil. These are installed in power substations to reduce the voltage from 10,000 volts to 220. If you transmit a voltage of 220 volts over a long distance through ordinary wires, the losses will be significant. As you know, the higher the voltage, the less effect the wire resistance has. From thermal power plants and state district power plants, a total of 100,000 volts are transmitted via Electric Transmission Lines!

Pulse transformer - not a single modern electrical appliance can do without it, be it a TV, laptop, computer or phone charger. As a rule, it operates at frequencies above 800 Hz in tandem with a PWM controller that increases the pulse frequency as the load increases. An ingenious invention that allows you to obtain large currents from a modest size. Compare the sizes of a traditional welding machine and a welding inverter operating on this principle.

How to distinguish the primary winding from the secondary winding in a transformer

There are three main features of the primary winding of a transformer:

1) In a step-down transformer, the resistance of the primary winding is much higher than the secondary.

2) As a rule, the primary winding is wound with a thinner wire.

4) If the transformer is sealed into the circuit, you can look at the terminals. In the secondary winding, as a rule, a diode bridge is switched on, followed by a high-capacity electrolytic capacitor (from 1000 μF). In the primary, a fuse is usually installed. For details on how to determine where the primary winding is, watch the video below.

How to ring the windings of a transformer?

If you have a gauge or a multimeter at your disposal, finding out where and which winding is not so difficult. We turn on the tester in resistance measurement mode (100 ohms) and ring the transformer terminals. Let's say the tester showed 89 ohms on one of the windings, and only 7 ohms on the other - accordingly, this is a secondary.

How to find out the no-load current of a transformer?

The no-load current is the current that the trans consumes without load; the lower it is, the better the transformer is designed and manufactured. Poor quality of the magnetic circuit, interturn short circuit, incorrect connection increase the no-load current. This current is converted into heat and if it is large (more than 20-100 mA) the trans can burn out. Switch the tester to current measurement mode and connect it in series with the primary winding of the transformer. Based on the measurement results, decide for yourself whether it is dangerous to use such a transformer.

Source

Voltage transformer

The voltage transformer can be classified more as electrical engineering than electronics. The most common single-phase voltage transformer looks like this.

If we fold back the top protection of the transformer, we can clearly see that it consists of some kind of iron frame, which is assembled from metal plates, as well as two coils that are wound on this iron frame. Here we see two black wires coming out of one coil

and on the other coil there are two red wires

Both of these coils are placed on the transformer core. That is, as a result we get something like this

Nothing complicated, right?

But then comes the most interesting part. If you apply alternating voltage to one of these coils, then alternating voltage also appears in the other coil. But how is this possible? After all, these windings do not touch each other at all and they are isolated from each other. What a miracle! It's all about the so-called electromagnetic induction.

To explain in simple terms, when an alternating voltage is applied to the primary winding, an alternating magnetic field with the same frequency will appear in the core. The second coil picks up this alternating magnetic field and already produces an alternating voltage at its ends.

Device principle

When considering how a voltage-increasing transformer works, you need to delve into the basic principles of the design. The basis for the operation of a transformer is the mechanism of electromagnetic induction. The metal core is in an insulating environment. The circuit includes two coils. The number of windings is not the same. Coils with more turns in the first circuit than in the second can increase the indicator.

AC voltage is supplied to the primary circuit. For example, this is a current in the network of 110 (100) V. A magnetic field appears. Its strength increases with the correct ratio of windings in the core. When electricity passes through the second winding in the step-up transformer, a current with a certain indicator appears. For example, an indicator of the characteristics of a 220 V network is provided.

In this case, the frequency remains the same. To supply direct current to the power supply line, a converter is installed in the circuit. This device can be used in boost-type equipment. The device is capable of working not only to change voltage, but also frequency. Certain equipment is powered by direct current.

Transformer windings

These same coils of wire in a transformer are called windings. The windings mainly consist of varnished copper wire. Such a wire is in varnish insulation, therefore, the wire in the winding does not short-circuit with each other. A winding transformer wire looks something like this.

It can be of different diameters. It all depends on what load this or that transformer is designed for.

The simplest single-phase transformer can have two such windings.

The winding to which voltage is applied is called the primary winding. People also call it “primary”. The winding from which the voltage has already been removed is called secondary or “secondary”.

In order to find out where the primary winding is and where the secondary is, just look at the transformer nameplate.

I/P: 220M50Hz (RED-RED) - this tells us that the two red wires are the primary winding of the transformer, to which we supply a mains voltage of 220 Volts. Why do I think this is primary? I/P means InPut, which is translated as “input”.

O/P: 12V 0.4A (BLACK, BLACK) – secondary winding of the transformer with an output voltage of 12 Volts (OutPut). The maximum current that this transformer can supply to the load is 0.4 Ampere or 400 mA.

Magnetic system

The magnetic core is a complex of plates or other elements made of electrical steel, arranged in a selected geometric configuration. The fields of the unit are concentrated in the design. The assembled magnetic core, together with the components and connecting elements, forms the core of the transformer. The part on which the windings are wound is the rod. The area of ​​the system intended to complete the circuit and not carrying any turns of the circuit is called the yoke. The arrangement of the rods in space serves to divide the system into the following types:

  • flat design in which all cores are located on a single surface;
  • spatial method - longitudinal rods or cores and yokes are in different planes;
  • symmetrical order - rods of the same length and shape are arranged so that their spatial arrangement applies equally to all elements and cores;
  • an asymmetrical structure involves rods of different types and sizes, located differently from similar parts.

Transformer formula

The main formula of a transformer looks like this.

U2 – voltage on the secondary winding

U1 – voltage on the primary winding

N1 – number of turns of the primary winding

N2 – number of turns of the secondary winding

k – transformation ratio

The transformer also observes the law of conservation of energy, that is, whatever power enters the transformer, such power leaves the transformer:

This formula is valid for an ideal transformer . A real transformer will produce slightly less power at the output than at its input. The efficiency of transformers is very high and sometimes even reaches 98%.

Types of transformers by design

Single-phase transformers

These are transformers that convert single-phase AC voltage of one value into single-phase AC voltage of another value.

Basically single-phase transformers have two windings, primary and secondary . One voltage value is applied to the primary winding, and the voltage we need is removed from the secondary winding. Most often in everyday life you can see so-called network transformers , in which the primary winding is designed for mains voltage, that is, 220 V.

In the diagrams, a single-phase transformer is designated as follows:

The primary winding is on the left, and the secondary winding is on the right.

Sometimes many different voltages are required to power different devices. Why put your own transformer on each device if you can get several voltages at once from one transformer? Therefore, sometimes there are several pairs of secondary windings, and sometimes even some windings are derived directly from the existing secondary windings. Such a transformer is called a transformer with multiple secondary windings. In the diagrams you can see something like this:

Three-phase transformers

These transformers are mainly used in industry and are most often larger in size than simple single-phase transformers. Almost all three-phase transformers are considered power transformers. That is, they are used in circuits where powerful loads need to be powered. This could be CNC machines and other industrial equipment.

In the diagrams, three-phase transformers are designated like this:

The primary windings are designated by capital letters and the secondary windings by small letters.

Here we see three types of winding connections (from left to right)

In 90% of cases, star-star is used.

Purpose

Step-down transformers are used in various fields of human activity. Power structures are installed at substations along the route of power lines. The presented types of devices reduce the current in the network from 380 to 220 V during operation. Household electrical appliances operate at this power. The presented installation is called an industrial current step-down transformer.

Household step-down varieties include devices that operate at lower powers. They accept 220 V to the primary circuit and output 42, 36, 12 V, taking into account consumer requirements.

Types of voltage transformers

A step-down transformer

This is a transformer that lowers the voltage. Let's say we supply 220 Volts to the primary winding and remove 12 Volts. In this case, the transformation coefficient (k) will be greater than 1 .

Step-up transformer

This is a transformer that increases the voltage. Let's say we supply 10 Volts to the primary winding, and remove 110 V from the secondary winding. That is, we increased our voltage 11 times. Step-up transformers have a transformation ratio less than 1 .

Isolation or isolation transformer

Such a transformer is used for electrical safety purposes. Basically, this is a transformer with the same number of windings at the input and output, that is, its voltage on the primary winding will be equal to the voltage on the secondary winding. The neutral terminal of the secondary winding of such a transformer is not grounded. Therefore, if you touch a phase on such a transformer, you will not get an electric shock. You can read about its use in the article about LATR. Isolating transformers have a transformation ratio of 1 .

Matching transformer

Such a transformer is used to match the input and output impedance between circuit stages.

Repair and service

A transformer is a complex piece of equipment. Periodic maintenance and repair will be required. It is recommended to entrust this work to professionals. Only a person with appropriate training has the right to carry out such work.

With an increased heating rate and the presence of noise, it is necessary to rewind the transformer circuits. This procedure can only be performed by an unqualified specialist with a minimum level of knowledge in the field of electrical engineering.

The device has a magnetic drive. It is common to coils. The first circuit is responsible for reducing, and the second circuit is responsible for increasing electricity in the network. Inspection of the transformer is carried out using a certain technology.

Examination

First, a visual inspection of the block is carried out. If overheating is observed during operation, deformations, irregularities, and swelling of the insulation appear on the surface. If the inspection does not reveal any deviations, you need to find the input and output of the device. The first of them is connected to the first coil. This is where a magnetic field appears when electricity is supplied. The output is connected to the secondary winding.

The output signal is filtered. This indicator needs to be measured. The collapsible parts of the housing structure are removed. You need to gain access to the microcircuits. This will allow you to measure the voltage with a multimeter. In this case, you will need to take into account the nominal indicators. If the measurement result is less than 80% of the value specified by the manufacturer, the primary circuit is not functioning correctly.

The first coil is disconnected from the device. It no longer receives electricity. Then the secondary circuit is checked. If there is no filtering, power from the measuring device is used. If there is no normal voltage in the system, the equipment requires repair.

After checking, if the component elements are in good condition, the structure is assembled in the reverse order. If necessary, the unit is repaired.

Operation of a step-down transformer in practice

So, we have a simple single-phase step-down transformer.

It is on it that we will conduct various experiments.

We connect the red primary winding to a 220 Volt network and measure the voltage on the secondary winding of the transformer without load. 13, 21 Volts, although it is written on the transformer that it should produce 12 Volts.

Now we connect the load to the secondary winding and see that the voltage has dropped.

I wonder how much current our incandescent lamp consumes? We insert a multimeter into the open circuit and measure.

Judging by the nameplate, it says that it can supply 400 mA to the load and the voltage will be 12 Volts, but as you can see, with a load close to 400 mA, our voltage dropped to almost 11 Volts. Here's a Chinese transformer for you. It should not be loaded with more than 400 mA. In this case, the voltage will drop even more, and the transformer will heat up like an iron.

How to check a transformer

How to check for short circuit in windings

Although the windings fit very tightly to each other, they are separated by a varnish dielectric, which covers both the primary and secondary windings. If there is a short circuit between the wires somewhere, the transformer will get very hot or make a strong hum during operation. It will also smell like burnt varnish. In this case, it is worth measuring the voltage on the secondary winding and comparing it so that it matches the passport value.

Checking for broken windings

If there is a break, everything is much simpler. To do this, we use a multimeter to check the integrity of the primary and secondary windings. So, the resistance of the primary winding of our transformer is slightly more than 1 KOhm. This means the winding is intact.

We check the secondary winding in the same way.

From this we conclude that our transformer is alive and well.

Similar articles on the topic “transformer”

Source

Interesting video: How does a transformer work?

Having examined the features and operating principles of step-up transformers, one can evaluate their importance in power lines. The use of such equipment improves the quality of electricity in household and industrial networks. It is installed everywhere. The presented types of installations are in high demand today.

Most electrical household devices operate on a 220 V power supply. Sometimes it is necessary to reduce this voltage to a certain value in order to connect low-voltage load consumers. Such consumers can be halogen lamps, low-voltage heaters, LED strips and many others.

This voltage reduction can be performed by step-down transformers, which can be purchased in a store or made independently. Such transformers are popular in electrical engineering and radio electronics, as well as in domestic environments.

Design Features

The main part of the transformer is a ferromagnetic core, on which there are two windings wound with a copper conductor. These windings are divided into primary and secondary, depending on the principle of operation. Mains voltage is supplied to the primary winding, and reduced voltage is removed from the secondary winding for load consumers.

The windings are interconnected by an alternating magnetic flux, which is induced in the ferromagnetic core. There is no electrical contact between the windings. The primary winding has more turns than the secondary. Therefore, the output voltage is reduced.

Typically, step-down transformers with all elements are located in the housing. However, not all models have it. This depends on the manufacturer, as well as the purpose of the step-down transformer.

Designation on the diagram

Operating principle

The operation of a step-down transformer can be described as follows. The operation of the transformer is based on the principle of electromagnetic induction. The voltage connected to the primary winding creates a magnetic field in it, which crosses the turns of the secondary winding. An electromotive force is generated in it, under the influence of which a voltage arises that is different from the input voltage.

The difference in the number of turns of the primary and secondary windings determines the difference between the input and output voltage of the step-down transformer. During the operation of the transformer, some losses of electricity occur, which are inevitable and amount to about 3% of the power.

To calculate the exact values ​​of the transformer parameters, you need to make certain calculations of its design. Electromotive force can occur when the transformer is connected to alternating current only. Therefore, most household electrical devices operate on AC power.

Step-down transformers are part of many power supplies, stabilizers and other similar devices. Some transformer models may contain multiple terminals on the secondary winding for different groups of connections. These types of devices have become popular because they are universal and multifunctional.

Varieties

Step-down transformers have different designs, depending on the design and principle of operation.

  • Toroidal . This version of the transformer model (Figure “a”) is also used for low powers and has a torus-shaped core. It differs from other models in its light weight and dimensions. Used in radio-electronic devices. Its design makes it possible to achieve a higher current density, since the winding is well cooled throughout the entire core, and the magnetizing current is the lowest.
  • Rod . Figure “b” shows a core view of a transformer, in which the windings cover the magnetic cores. Such models are most often made for medium and high power devices. Their design is quite simple and makes it easier to insulate and repair windings. Their advantage is good cooling, as a result of which fewer conductors are required for the windings.
  • Armored . In this type of transformer (Figure “c”), the magnetic circuit covers the windings in the form of armor. The remaining parameters are identical to the rod type, with the exception that armored transformers are generally low-power, since they have less weight and price compared to the previous version, due to simple assembly and fewer coils.
  • Multi-winding . The most popular are two-winding 1-phase step-down transformers.

Step-up and step-down transformer

A huge number of different electronic devices, instruments and equipment are used in everyday life and at work. Quite often, their normal operation requires a step-up and step-down transformer. Each of them works on the basis of self-induction, which allows you to change the current in one direction or another. The name transformer itself means change or transformation. They are mainly used in conjunction with foreign-made electronics designed for currents that differ from domestic standards. In addition, transformers protect electrical equipment and optimize its power supply, making operation as efficient as possible.

Functions and operation of transformers

In electronics, transformers are indispensable devices. However, for them to work most effectively, it is necessary to have a good understanding of what the transformer is stepping down or stepping up. Depending on the needs, they increase or, conversely, decrease the potential in circuits with alternating current.

With the advent of different transformer devices, it became possible to deliver electricity over significant distances. Losses on power line wires are noticeably reduced when the alternating voltage increases and the current decreases. This occurs along the entire length of the conductors connecting the power plant with connected consumers. At each end of such lines, the voltages are reduced to a safe level, facilitating the operation of the equipment used.

Which transformer is called step-up and which is called step-down, and what is the difference between them?

The short answer is that a device that produces a higher potential, compared to the input, is considered a booster. If the reverse process occurs, and the potential at the output is less than at the input, such a device will be a step-down device. In the first case, the secondary winding has a larger number of turns than the primary, and in the second, on the contrary, a secondary winding with fewer turns is used. This is how they differ radically from each other.

Can a step-down transformer be used as a step-up transformer?

Yes, you can. Since to change the functions it is enough to change the connection diagram of the windings with the potential source and the load. Accordingly, the functionality of the step-down transformer will change.

In practice, in order to improve the efficiency of the device, the inductance of all windings is calculated for the exact operating values ​​of current and voltage. These indicators must be maintained in their original state when the step-up and step-down transformer change their functions to the opposite.

How to determine which winding belongs to one or another

Structurally, transformers are made according to such a principle that it is impossible to immediately determine their differences, that is, which wires are called and actually are the primary, and which of them are the secondary winding. Therefore, to avoid confusion, markings are used. The symbol “H” is provided for the high-voltage winding; in step-down devices it serves as the primary winding, and in step-up devices it serves as the secondary winding. Low voltage windings are marked with an “X”.

In order to understand the features, differences and operating principle of each of these devices, they should be considered in more detail.

Varieties

The category of boosting types of equipment includes a number of devices that differ in design, purpose, and technical characteristics:

  1. Autotransformer. It has one combined winding.
  2. Power. The most common type among devices that increase voltage.
  3. Anti-resonant. Has a closed design. Due to their special operating principle, they have compact dimensions.
  4. Grounded. The windings are connected in a star or zigzag pattern.
  5. Peak transformers. Separate direct and alternating current.
  6. Household. The improvement in the characteristics of electricity during the operation of a transformer is carried out in a small range. They help eliminate interference in the household network, protect equipment from surges, low and high electricity.

The presented designs differ in power and technical characteristics.

General structure and operation of step-down transformers

Transformers convert a higher input voltage into a lower output voltage characteristic, that is, they allow large currents to be reduced to the required values. If necessary, such a device can be used as a booster.

The operating principle of these devices is determined by the law of electromagnetic induction. The standard design consists of two windings and a core. The primary winding is connected to the power source, after which a magnetic field is generated around the core. Under its influence, an electric current with certain specified voltage parameters appears in the secondary winding.

The output power is determined by the quantitative ratio of turns in each coil. By changing this indicator, you can control the characteristics of the output voltage and obtain the required current for household and industrial equipment.

It is impossible to change the frequency of electric current using transformers alone. For this purpose, the design of the step-down apparatus is supplemented with a rectifier that changes the frequency of the current in the range of required values. Modern devices are complemented by semiconductors and integrated circuits with capacitors, resistors, microcircuits and other components. The result is a device with small dimensions and weight, but a fairly high level of efficiency, working to reduce voltage.

Such transformers operate very quietly and are not subject to strong heating. The output current power can be set by adjustments and differs in each case. All new type devices are equipped with short circuit protection.

The step-down transformer has a simple and reliable circuit; it is widely used at substations between sections of power lines. They reduce the mains current from 380 to 220 volts. Such devices are industrial. Those used in everyday life are characterized by lower power. Taking 220 V on the primary winding of the input, they then produce a reduced voltage from 12 to 42 volts in accordance with the connected consumers. The transformation ratio of step-down devices is always below unity. In order to determine it, you need to know the ratio between the number of turns in the primary and secondary windings.

Applications in networks

The devices are installed in electrical lines and power supplies of consumer points. According to the Joule-Lenz law, as the current increases, heat is released, which heats the wire. To transmit energy over long linear distances, the voltage is increased and the currents are decreased. When reaching the consumer, the power is reduced, since for safety reasons it would be necessary to use massive insulation.

At the beginning of the chain, a step-up transformer is installed, and at the receiving point the indicators are reduced. Such combinations are used repeatedly along power lines, achieving favorable conditions for transporting electricity and creating acceptable values ​​for the consumer.

Due to the presence of three phases in the network, three-phase units are used for energy transformation. Sometimes a group is used in which the devices are combined into a star model, with a common conducting rod.

Although the efficiency of high-power units reaches almost one hundred percent, a lot of heat is still generated. A typical 1 GW power plant transformer produces several megawatts. To reduce this phenomenon, a cooling system has been developed in the form of a tank containing non-flammable liquid or transformer oil and a strong air heat distribution device. Cooling is often water-based; the dry principle is used at low power.

Rating
( 1 rating, average 4 out of 5 )
Did you like the article? Share with friends: